*D/SINGLEPOINT/FILTER File Listing

This is a listing of the *D/SINGLEPOINT/FILTER and *D/SINGLEPOINTTEST/FILTER files. The contents of these files as released are identical.

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%1000000039.000.001
%% This is the filter file for the Opeartions Sentinel Interface 		%%1001000002.000.000
%% for ClearPath MCP. The program which uses this file is called 		%%1002000002.000.000
%% 																								%%10030000
%% 				OBJECT/SINGLEPOINT/INTERFACE 										%%10040000
%% 																								%%10050000
%% Filters can be added and deleted from this file to suit your 			%%1006000002.000.000
%% site’s specific needs. The name of the filter file can be changed 	%%1007000002.000.000
%% by updating FILTER_FILE_NAME in the configuration file. 				%%1008000002.000.000
%% 																								%%1008500002.000.000
%% The format for the parameters is: 												%%10090000
%% 																								%%10100000
%% 		 <Major type>,<Minor type> [LOG_COMPATIBILITY {1|2}]				%%1011000002.002.001
%% 																								%%10120000
%% Operations Sentinel Interface interprets the following types: 		%%1013000002.000.000
%% 																								%%10140000
%% 		1,1	   1,2	 1,3	 1,4 	  2,12	 2,20	  2,21 						%%10150000
%% 		3,1	   3,2	 3,3	 3,4	  3,5	   3,6		3,7	3,8	 3,9  or 3,ALL%%10160000
%% 		6,3	   14,1	 14,4	 14,9	  14,10  or 14,ALL 							%%10170000
%% 		15,1     15,2	 15,3	 15,5														%%10172000
%% 																								%%10180000
%% 		If ’ALL’ is used for major type ’3’ or ’14’ then all minor 		%%10190000
%% 		types for that major type are monitored. 								%%10200000
%% 																								%%1020200002.000.000
%% Operations Sentinel Interface calls JOBFORMATTER to interpret 		%%1020400002.000.000
%% other <major>,<minor> type pairs.  												%%1020600002.000.000
%% 																								%%1021000002.000.000
%% The starting and ending indicators must be present in the filter 	%%10220000
%% file in order for it to load correctly. The indicators are: 			%%10230000
%% 																								%%10240000
%% 					Starting indicator: FILTERTYPES 								%%10250000
%% 					Ending indicator: 	ENDFILTERTYPES 							%%10260000
%% 																								%%10270000
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%10280000
																								 	  10290000
FILTERTYPES 																					  10300000
	1,1 							% BOJ 														  1031000002.001.000
	1,2 							% EOJ 														  1032000002.001.000
	1,3 							% BOT 													     1033000002.001.000
	1,4 							% EOT 														  1034000002.001.000
	2,12 							% Mainframe Error 										  1035000002.001.000
	2,21 							% I/O Exception 											  1037000002.001.000
	6,3 							% SETSTATUS 												  1037200002.001.000
	14,ALL 						% Multilingual System (MLS) Message 				  1038000002.001.000
	15,1 							% Volume Online 											  1038200002.001.000
	15,2 							% Volume Offline 											  1038400002.001.000
	15,3 							% Volume Purged 											  1038600002.001.000
	15,5 							% Tape Volume New File 							     1038800002.001.000
ENDFILTERTYPES 																				  10390000