This is a listing of the *COMS/SINGLEPOINT/LOAD file. You must edit this file before starting the interface software. The parameters that you must modify are in bold type:
Usercode on lines 10100000 and 10202000
Replace these values with the installation usercode (usercode-2). See 3.1.
MIN_COPIES on line 10205000, if you want the test instance of SINGLEPOINT to start automatically.
Usercode and disk family on line 10230000. Note that the data bolded on this line as shown here is not in the supplied load file, so you must add it. Replace these values with the usercode-2 and installation pack you specified during installation. See 3.1.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%1000000039.000.001 %% This is the COMS load file for the Operations Sentinel %%1001000002.000.000 %% Interface for ClearPath MCP. Before loading this file into COMS %%1002000002.000.000 %% utility, change the packnames and usercodes under program and %%1003000002.000.000 %% library to match where they will be located at your site. %%10040000 %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%10050000 10060000 CREATE PROGRAM SINGLEPOINT 10070000 REMOTE_FILE = N ,QUEUE_DEPTH = 0 10080000 ,TITLE = OBJECT/SINGLEPOINT/INTERFACE 10090000 ,USERCODE = SPO 10100000 ,CHARGECODE = "." 10120000 ,TASK_EQUATION = "OPTIONS = FAULT, DSED, ARRAYS, AUTORM, 1012500002.000.000 LIBRARIES, TODISK; FILE TOSPO (DIALOGCHECKINTERVAL=1);MPID=SINGLEPOINT;"1013000002.002.001 ,SECURITY_CATEGORY_LIST = ALL 10140000 ,DATABASE = TPLIBRARY 10150000 ,MIN_COPIES = 1 ,MAX_COPIES = 1 1016000002.001.000 ,INITIATION_TIME_LIMIT = 00:00 10170000 ,TERMINATION_TIME_LIMIT = 00:00 ,INPUT_QUEUE_MEMORY_SIZE = 0 10180000 ,INSTALLATION_DATA = NONE 10190000 ; 10200000 CREATE PROGRAM SINGLEPOINTTEST 1020050002.000.000 REMOTE_FILE = N ,QUEUE_DEPTH = 0 1020100002.000.000 ,TITLE = OBJECT/SINGLEPOINT/INTERFACE 1020150002.000.000 ,USERCODE = SPO 1020200002.000.000 ,CHARGECODE = "." 1020250002.000.000 ,TASK_EQUATION = "OPTIONS = FAULT, DSED, ARRAYS, AUTORM, 1020300002.000.000 LIBRARIES, TODISK; FILE CONFIGFIL(TITLE=D/SINGLEPOINTTEST/CONFIG); 1020350002.002.000 FILE TOSPO (DIALOGCHECKINTERVAL=1);MPID=SINGLEPOINTTEST;" 1020360002.002.001 ,SECURITY_CATEGORY_LIST = ALL 1020400002.000.000 ,DATABASE = TPLIBRARY 1020450002.000.000 ,MIN_COPIES = 0 ,MAX_COPIES = 1 1020500002.000.000 ,INITIATION_TIME_LIMIT = 00:00 1020550002.000.000 ,TERMINATION_TIME_LIMIT = 00:00 ,INPUT_QUEUE_MEMORY_SIZE = 0 1020600002.000.000 ,INSTALLATION_DATA = NONE 1020650002.000.000 ; 1020700002.000.000 CREATE LIBRARY SINGLEPOINT 10210000 TITLE = 10220000 OBJECT/SINGLEPOINT/INTERFACE/LIB 1023000002.000.000 ,INSTALLATION_DATA = NONE 10240000 ; 10250000 CREATE PROCESSING_ITEM SINGLEPOINT 10260000 LIBRARY = SINGLEPOINT 10270000 ,DEVICE_TYPE_LIST = ALL 10280000 ,ACTUALNAME = "SINGLEPOINT_INPUT_PI" 10290000 ,INSTALLATION_DATA = NONE 10300000 ; 10310000 CREATE PROCESSING_ITEM_LIST SINGLEPOINT 10320000 INSTALLATION_DATA = NONE 10330000 =SINGLEPOINT 10340000 ; 10350000 CREATE AGENDA SINGLEPOINT_MARC OF MARC 10360000 DESTINATION = MARC 10370000 ,PROCESSING_ITEM_LIST = SINGLEPOINT 10380000 ,DEFAULT_INPUT = N ,DEFAULT_OUTPUT = N 10390000 ,TRANSACTION_MODE_AGENDA = N ,SET_TRANSACTION_MODE = N 10400000 ,INPUT_QUEUE_PROTECTION = N ,WAIT_FOR_COMPLETION = N 10410000 ,INSTALLATION_DATA = NONE 10420000 ; 10430000