*COMS/SINGLEPOINT/LOAD File Listing

This is a listing of the *COMS/SINGLEPOINT/LOAD file. You must edit this file before starting the interface software. The parameters that you must modify are in bold type:

%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%1000000039.000.001
%% This is the COMS load file for the Operations Sentinel					%%1001000002.000.000
%% Interface for ClearPath MCP. Before loading this file into COMS		%%1002000002.000.000
%% utility, change the packnames and usercodes under program and			%%1003000002.000.000
%% library to match where they will be located at your site. 				%%10040000
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%10050000
																									  10060000
CREATE		 PROGRAM 		SINGLEPOINT													  10070000
  REMOTE_FILE						= N				 ,QUEUE_DEPTH  		 = 0	  10080000
 ,TITLE								= OBJECT/SINGLEPOINT/INTERFACE 				  10090000
 ,USERCODE 							= SPO 												  10100000
 ,CHARGECODE 						= "." 												  10120000
 ,TASK_EQUATION 					= "OPTIONS = FAULT, DSED, ARRAYS, AUTORM, 1012500002.000.000
LIBRARIES, TODISK; FILE TOSPO (DIALOGCHECKINTERVAL=1);MPID=SINGLEPOINT;"1013000002.002.001

 ,SECURITY_CATEGORY_LIST 		= ALL									 					10140000
 ,DATABASE 							= TPLIBRARY												10150000
 
 ,MIN_COPIES 						= 1				,MAX_COPIES					 = 1  1016000002.001.000
 ,INITIATION_TIME_LIMIT 			= 00:00													10170000
 ,TERMINATION_TIME_LIMIT 		= 00:00		,INPUT_QUEUE_MEMORY_SIZE	 = 0	10180000
 ,INSTALLATION_DATA 				= NONE													10190000
;																										10200000
CREATE	  PROGRAM		 SINGLEPOINTTEST													1020050002.000.000
	 REMOTE_FILE						= N 			 ,QUEUE_DEPTH					 = 0  1020100002.000.000
	,TITLE								= OBJECT/SINGLEPOINT/INTERFACE					1020150002.000.000
	,USERCODE							= SPO														1020200002.000.000
	,CHARGECODE							= "."														1020250002.000.000
	,TASK_EQUATION					 	= "OPTIONS = FAULT, DSED, ARRAYS, AUTORM,	1020300002.000.000
LIBRARIES, TODISK; FILE CONFIGFIL(TITLE=D/SINGLEPOINTTEST/CONFIG);			1020350002.002.000
FILE TOSPO (DIALOGCHECKINTERVAL=1);MPID=SINGLEPOINTTEST;"						1020360002.002.001
	,SECURITY_CATEGORY_LIST  		= ALL														1020400002.000.000
	,DATABASE							= TPLIBRARY												1020450002.000.000
	,MIN_COPIES							= 0			 ,MAX_COPIES					 = 1 	1020500002.000.000
	,INITIATION_TIME_LIMIT	 		= 00:00													1020550002.000.000
	,TERMINATION_TIME_LIMIT	 	= 00:00	 ,INPUT_QUEUE_MEMORY_SIZE	 	 = 0	1020600002.000.000
	,INSTALLATION_DATA			 	= NONE													1020650002.000.000
;																										1020700002.000.000
CREATE LIBRARY		 SINGLEPOINT															10210000
	 TITLE								=															10220000
OBJECT/SINGLEPOINT/INTERFACE/LIB															1023000002.000.000
	,INSTALLATION_DATA			 	= NONE													10240000
;																										10250000
CREATE	 PROCESSING_ITEM	 SINGLEPOINT													10260000
	 LIBRARY								= SINGLEPOINT											10270000
	,DEVICE_TYPE_LIST				 	= ALL														10280000
	,ACTUALNAME							= "SINGLEPOINT_INPUT_PI"							10290000
	,INSTALLATION_DATA				= NONE													10300000
;																										10310000
CREATE	 PROCESSING_ITEM_LIST SINGLEPOINT												10320000
	 INSTALLATION_DATA				= NONE													10330000
			=SINGLEPOINT																			10340000
;																										10350000
CREATE	 AGENDA		 SINGLEPOINT_MARC	 OF MARC											10360000
	 DESTINATION						= MARC													10370000
	,PROCESSING_ITEM_LIST			= SINGLEPOINT											10380000
	,DEFAULT_INPUT						= N ,DEFAULT_OUTPUT							= N	10390000
	,TRANSACTION_MODE_AGENDA	 	= N ,SET_TRANSACTION_MODE					= N	10400000
	,INPUT_QUEUE_PROTECTION		= N ,WAIT_FOR_COMPLETION					= N	10410000
	,INSTALLATION_DATA				= NONE													10420000
;																										10430000